Skip to main content

Series 400-AF

Wipe for special requirements

Back to our wipes for special requirements

Series 400-AF, a microfibre wipe made of 70% polyester and 30% polyamide, is versatile, both in microbiological controlled areas and in purely particle controlled areas. The hydro-entangled non-woven construction gives the wipe a very high abrasion and tear resistance. In addition, it is free of adhesives and binding agents, which is ultimately reflected in the low extractable residues. Due to the microfibre construction, its strength lies in its cleaning efficiency. In many cases, even difficult soiling can be removed more easily and quickly with relatively little expenditure of time. Compared to the polyester-cellulose non-woven wipes or 100% polyester non-woven wipes, the series 400-AF has a significantly lower particle emission and can definitely compete with knitted polyester wipes.

 

 

Facts

Particle emission (dry)
Particle emission (wet)
Abrasion resistance
Wet cleaning
Dry cleaning
Chemical permanence
Electrostatic behaviour
Softness
Sealed edges
decontaminated
sterile

Special requirements

Series 400-AF

Microfibre non-woven, 70% PES/30% PA, water jet consolidated

-
-
-

Properties

  • 70% polyester / 30% polyamide 
  • water-jet compacted microfibre non-woven fabric
  • cold cut edges
  • packed in a single PE-bag

Advantages

  • good absorbency measured by mass per unit area
  • abrasion and tear resistant
  • good resistance to chemicals normally used in cleanrooms
  • soft handle and gentle on scratch-sensitive surfaces

Applications

  • cleaning wipe especially for critical areas
  • cleaning wipe for areas where high absorbency and cleanliness are required
  • cleaning wipe for optical surfaces, as well as other similarly sensitive surfaces

Product recommen­dation based on cleanroom classes


123456789low dust


ABCDE

Of course, cleanroom wipes used in ISO 5 can also be used in ISO 9, but in this case the economic efficiency and usefulness should be considered.

A 1 to 1 allocation of cleanroom wipes to an air cleanliness class according to ISO 14644-1 is not possible. Recommendations can only be made on the basis of special properties relevant from a cleanroom technical point of view, such as "abrasion resistance" or "particle emission". Users can find further information on this in VDI Guideline 2083 Part 9.2.

Technical data

Properties   Unit of measurementValueTest method
Material     70% PES / 30% PA ASTM D629
Standard Test Methods for Quantitative Analysis of Textiles
Edge processing     cold cut  
Mass per unit area   g/m2 ± 5% 60  
Absorptive capacity
(Ai) intrinsic
(Ae) extrinsic
 
ml/g
ml/m2

n. s.
212.5
IEST-RP-CC004.3
Section 8.3
Absorbency rate   second 1 IEST-RP-CC004.3
Section 8.2
NVR
Non-volatile residues
IPA based
DI water based
µg/cm2
µg/cm2
n. d.
2.3
IEST-RP-CC004.3
Section 7.1
Particle residues 0.1 – ≤ 0.2 µm
> 0.2 – ≤ 0.5 µm
> 0.5 – ≤ 1.0 µm
> 1.0 µm
number/cm2 5,030
4,670
1,470
366
IEST-RP-CC004.3
Section 6.1.3 and 6.2.1
Biaxial shake test & per liquid(-borne) particle counter (LPC)
Fibre residues > 100 µm fibres/cm2 n.s. IEST-RP-CC004.3
Section 6.1.3 and 6.2.1
Ionic residues Ammonium (NH4+)
Bromide (Br-)
Calcium (Ca+)
Chloride (ClO2-)
Fluorine (Fl-)
Iodine (I+)
Lithium (Li+)
Magnesium (Mg+)
Nitrate (NO3-)
Nitrite (NO2-)
Phosphate (PO43-)
Potassium (K+)
Sodium (Na+)
Sulphate (SO42-)
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
µg/cm2
0.0033
112
0.0757
n. d.
n. d.
n. d.
n. d.
n. d.
0.0216
not tested
n. d.
0.0053
0.825
0.424
IEST-RP-CC004.3
Section 7.2.2
measured by ion chromatograph
Organic contaminants silicone oil
amides
D-n-octylphthalate (DOP)
  n. s.
n. s.
n. s.
by FTIR spectrometer
Fourier transform infrared spectrometer
  DimensionsPU in a bagPU per carton  
  9" x 10"
(~ 23 x 25 cm)
300 pieces 12  
      n. s. = not specified
n. d. = not detectable
 

Note

The manufacturer's technical data listed above are typical values at the time of publication. They are not specifications. All data are without guarantee, changes are possible without prior notice.
Due to different test methods depending on the respective manufacturers and test laboratories, most of the given values cannot be compared one-to-one with those of other manufacturers/wipes.
Independent tests can be commissioned on request.